Mitsubishi Electric C70 Setup Manual page 400

Hide thumbs Also See for C70:
Table of Contents

Advertisement

【#7514】 <check> Selection of area check method PSW2
When position switch area checking at high speed is selected, specify the mode of area checking,
i.e., whether to use the command type machine position or detector feedback position, for each
position switch point.
0: Use the command type machine position as the machine position for position switch area
1: Use the detector feedback position as the machine position for position switch area checking.
【#7521】 <axis> Axis name PSW3
Specify the name of the axis for which a position switch is provided.
---Setting range---
NC axis: axis name (X, Y, Z, U, V, W, A, B, or C)
PLC axis: PLC No. (1 to 8)
【#7522】 <dog1> Imaginary dog position 1 PSW3
When the machine enters the range between imaginary dog positions 1 and 2, a signal is output to
the PLC.
Part system 1 device: X662
Part system 2 device: X6E2
---Setting range---
-99999.999 to 99999.999 (0.001mm)
【#7523】 <dog2> Imaginary dog position 2 PSW3
When the machine enters the range between imaginary dog positions 1 and 2, a signal is output to
the PLC.
Part system 1 device: X662
Part system 2 device: X6E2
---Setting range---
-99999.999 to 99999.999 (0.001mm)
【#7524】 <check> Selection of area check method PSW3
When position switch area checking at high speed is selected, specify the mode of area checking,
i.e., whether to use the command type machine position or detector feedback position, for each
position switch point.
0: Use the command type machine position as the machine position for position switch area
1: Use the detector feedback position as the machine position for position switch area checking.
【#7531】 <axis> Axis name PSW4
Specify the name of the axis for which a position switch is provided.
---Setting range---
NC axis: axis name (X, Y, Z, U, V, W, A, B, or C)
PLC axis: PLC No. (1 to 8)
【#7532】 <dog1> Imaginary dog position 1 PSW4
When the machine enters the range between imaginary dog positions 1 and 2, a signal is output to
the PLC.
Part system 1 device: X663
Part system 2 device: X6E3
---Setting range---
-99999.999 to 99999.999 (0.001mm)
checking.
checking.
C70 Setup Manual
Appendix 1.13 Position Switches
383

Advertisement

Table of Contents
loading

Table of Contents