10.2.2.1 Restoration procedures
The following shows the restoration procedures.
(1) Set "OFF" the CF Card access switch.
(2) Insert the CF Card that has backup data into the card slot.
(3) Set "ON" the CF Card access switch.
(4) Open the GOT Utility screen. The utility call key(s) is set as follows at factory shipment.
For GT15: Press the right and left top corners together.
For GT16: Press the left top corner.
(Note)
The utility call key(s) can be arranged on the "GOT Setup" screen. For details, refer to the following
manuals.
For GT Designer3: "GT Designer3 Version1 Screen Design Manual (Fundamentals)" (SH(NA)-080866)
Section 4.
For GT Designer2: "GT Designer2 Version2 Screen Design Manual" (SH(NA)-080530) Section 3.
ON
OFF
10.2 PLC/CNC CPU Data Backup and Restoration
CF card
C70 Setup Manual
OFF
ON