Mitsubishi Electric C70 Setup Manual page 204

Hide thumbs Also See for C70:
Table of Contents

Advertisement

【#1100】 Tmove Tool compensation
Select when to perform tool length compensation and wear compensation.
0: Compensate when T command is executed.
1: Superimpose and compensate with the travel command in the block where the T command is
2: Compensate the wear amount when the T command is executed. Superimpose and
【#1101】 Tabsmv Tool compensation method
Select the type of travel command when "#1100 Tmove" is set to "1" or "2".
0: Compensate regardless of the travel command type
1: Compensate only at the travel command in the absolute command
【#1102】 tlm Manual tool length measuring system (for L system only)
Select the measurement method for manual tool measurement l.
0: Align tool with basic point
1: Input measurement results
【#1103】 T_Life Validate life management
Select whether to use the tool life management.
0: Not use
1: Use
【#1104】 T_Com2 Tool command method 2
Select how to handle the tool command in the program when "#1103 T_Life" is set to "1".
0: Handle the command as group No.
1: Handle the command as tool No.
【#1105】 T_Sel2 Tool selection method 2
Select the tool selection method when "#1103 T_Life" is set to "1".
0: Select in order of registered No. from the tools used in the same group.
1: Select the tool with the longest remaining life from the tools used or unused in the same group.
【#1106】 Tcount Life management (for L system only)
Select the input method when address N is omitted in inputting the data (G10 L3 command) for tool
life management function II.
0: Time specified input
1: Number of times specified input
【#1107】 Tllfsc Split life management display screen (for L system only)
Set the number of groups to be displayed on the tool life management II (L system) screen.
0: Displayed group count 1, maximum number of registered tools: 16
1: Displayed group count 2, maximum number of registered tools: 8
2: Displayed group count 4, maximum number of registered tools: 4
【#1108】 TlrectM Life management re-count M code (for L system only)
Set the M code for tool life management II (L system) re-count.
---Setting range---
0 to 99
【#1109】 subs_M Validate alternate M code
Select the user macro interrupt with the substitute M code.
0: Disable alternate M code
1: Enable alternate M code
located. If there is no travel command in the same block, compensation will be executed after
the travel command is superimposed in the next travel command block.
compensate the tool length compensation amount with the travel command in the same block.
If there is no travel command in the same block, compensation will be executed after the travel
command is superimposed in the next travel command block.
Appendix 1.3 Base Specifications Parameters
C70 Setup Manual
187

Advertisement

Table of Contents
loading

Table of Contents