【#2004】 G0tL G0 time constant (linear)
Set a linear control time constant for rapid traverse acceleration and deceleration.
The time constant will be enabled when LR (rapid traverse feed with linear acceleration/deceleration)
or F (soft acceleration/deceleration) is selected in "#2003 smgst Acceleration and deceleration
modes".
Speed
---Setting range---
1 to 4000 (ms)
【#2005】 G0t1 G0 time constant(primary delay) / Second-step time constant for soft
acceleration/deceleration
Set a primary-delay time constant for rapid traverse acceleration and deceleration.
The time constant will be enabled when R1 (rapid traverse feed with primary delay) or R3
(exponential acceleration and linear deceleration) is selected in "#2003 smgst Acceleration and
deceleration modes".
When the soft acceleration/deceleration is selected, the second-step time constant will be used.
<Rapid traverse feed with primary delay>
Speed
<Rapid traverse feed with exponential acceleration and linear deceleration>
Speed
<Soft acceleration/deceleration>
- When "#1219 aux03/bit7" is set to "0"
Speed
(Note) The time constant setting for the soft acceleration/deceleration can be changed by the setting
---Setting range---
1 to 5000 (ms)
【#2006】 G0t2
Not used. Set to "0".
G0tL
G0tL
G0t1
G0t1
2 x G0t1
G0t1
G0t1
G0t1
G0t1
G0t1
G0tL
G0tL
of "#1219 aux03/bit7"
Appendix 1.4 Axis Specifications Parameters
Time
Time
Time
Time
C70 Setup Manual
233