Appendix 2.16.3.4 Parameter Numbers During Initial Parameter Error - Mitsubishi Electric C70 Setup Manual

Hide thumbs Also See for C70:
Table of Contents

Advertisement

MITSUBISHI CNC
Appendix 2 Explanation of Alarms

Appendix 2.16.3.4 Parameter numbers during initial parameter error

If an initial parameter error (alarm 37) occurs, the alarm and the No. of the parameter set exceeding the setting range will
appear on the NC Diagnosis screen as shown below.
S02 Initial parameter error ○○○○□
If an error No. larger than the servo parameter No. is displayed for the servo drive unit, the alarm is occurring for several
related parameters. Refer to the following table, and correctly set the parameters.
Error parameter No.
2301
2302
2303
2304
2305
13001 to 13256
588
○○○○ : Error parameter No.
: Axis name
Details
The following settings are overflowing.
[1] Electronic gears
[2] Position loop gain
[3] Speed feedback
The absolute position parameter is valid when a high-speed serial
incremental detector (OSE104 or OSE105) is connected.
[1] Replace the detector to the one with absolute position specification.
No servo option is found.
[1] The closed loop (including the ball screw end)
[2] Dual feedback control function
No servo option is found.
[1] SHG control function
No servo option is found.
[1] Adaptive filtering function
Parameter error
The parameter value is outside the tolerable range.
The alarm No. is the No. of the spindle parameter where an error occurred.
Related parameters
SV001, SV002 SV003, SV018
SV019, SV020
SV049
SV017, SV025
SV025
SV017
SV057
SV058
SV027
Check the indicated spindle
parameter.