【#1220】 aux04
bit06: MDI part system interlock enabled
Select the part system in which the MDI setting is completed when pushing down the input during
editing MDI.
0: All the part systems
1: Only the part system being displayed
【#1223】 aux07
bit3: Synchronous tapping in-position check valid
0: Disable (Conventional method: execute same in-position check at the hole bottom/R point)
1: Enable (Extension method: able to select the in-position check enable/disable at the hole
Related parameters:
#1223/bit4 Synchronous tapping hole bottom in-position check
bit4: Synchronous tapping hole bottom in-position check
Select enable/disable of Synchronous tapping hole bottom in-position check.
0: Disable
1: Enable
bit6: Synchronous tapping (,S) cancel
0: Retain a spindle speed (, S) when performing synchronous tapping retract.
1: Cancel a spindle speed (, S) by retract with G80.
bit7: Synchronous tapping method
Select a synchronous tapping method.
0: Enable multi-step acceleration/deceleration and rapid return synchronous tapping
1: Disable multi-step acceleration/deceleration and rapid return synchronous tapping
【#1224】 aux08
bit0: Data sampling valid
Set valid/invalid for the data sampling.
0: Setting of sampling parameter invalid
1: Setting of sampling parameter valid
【#1225】 aux09
bit5: Alarm history recording option of the safety observation warning
Select whether to record "Y21 Safety observation warning 0001" (Speed obsv signal: Speed over) to
the alarm history.
0: Record
1: Not record
bottom/R point)
Appendix 1.3 Base Specifications Parameters
C70 Setup Manual
203