MITSUBISHI CNC
Appendix 1 Explanation of Parameters
【#29072(PR)】 Down Node Detect. Disable St. PLC side Device
Down node detection read device
Set a device to store the following data:
The down node detection disabled status is stored.
Bit settings
0: The slave down signal (X04) is turned ON when the corresponding slave node is down.
1: The slave down signal (X04) is NOT turned ON when the corresponding slave node is down.
<1st word>
bit0: 0th slave node
bit1: 1st slave node
bitF: 15th slave node
<2nd word>
bit0: 16th slave node
bit1: 17th slave node
bitF: 31st slave node
<3rd word>
bit0: 32nd slave node
bit1: 33rd slave node
bitF: 47th slave node
<4th word>
bit0: 48th slave node
bit1: 49th slave node
bitF: 63rd slave node
---Setting range---
Within the number of device points set in the PC parameter's device setting.
【#29073(PR)】 Present Link Scan Time PLC side Device Present link scan time
Set the device where the current link scan time is stored. (unit: ms)
---Setting range---
Within the number of device points set in the PC parameter's device setting.
【#29074(PR)】 Minimum Link Scan Time PLC side Device Minimum link scan time
Set the device where the minimum link scan time since the power has been turned ON is stored.
(unit: ms)
---Setting range---
Within the number of device points set in the PC parameter's device setting.
【#29075(PR)】 Maximum Link Scan Time PLC side Device Maximum link scan time
Set the device where the maximum link scan time since the power has been turned ON is stored.
(unit: ms)
---Setting range---
Within the number of device points set in the PC parameter's device setting.