Clock Quality And Status Management; Table 2-6 Parameter Description: Clock Synchronization Status - Huawei OptiX OSN 550 Configuration Manual

Multi-service cpe optical transmission system
Table of Contents

Advertisement

2 Creating the Network
Field
Effective Status
Lock Status
Switching Source
Switching Status

2.8.3 Clock Quality and Status Management

You can manage the quality and status of a clock to ensure the stability and precision of the
clock source that is currently traced.
Table 2-6

Table 2-6 Parameter description: clock synchronization status

Field
NE Name
NE Clock Working Mode
2-30
Value Range
Valid, Invalid
Lock, Unlock
Default value: Unlock
For example: 1-SL1D-1
(SDH-1)
Forced Switching, Manual
Switching, Normal
lists the parameters that are used for managing the quality and status of a clock.
Value Range
For example: NE(9-5595)
Normal Mode, Holdover
Mode, Free-Run Mode
Default value: -
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
Description
Specifies whether the clock
source is valid. This
parameter is used for query
only.
The Lock Status parameter
indicates the lock status of a
clock source in the priority
table.
You can click
7.124 Lock
Status
to display the detailed
information.
Displays the clock source to
be traced by the NE after the
switching.
Displays the switching status
of the current clock source.
Description
Displays the name of the NE.
The NE Clock Working
Mode parameter is used to
set the current working mode
of the system clock to the
normal, holdover or free-run
mode.
You can click
7.127 NE
Clock Working Mode
to
display the detailed
information.
Issue 02 (2011-06-30)