Deleting Dcn Communication Cables; Modifying The Service Configuration Data; Modifying Sdh Services - Huawei OptiX OSN 550 Configuration Manual

Multi-service cpe optical transmission system
Table of Contents

Advertisement

OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
Maintainer, Remarks, and Disabled Status. Click OK. Then, click Close in the Operation
Result dialog box indicating that the operation succeeded.
----End

5.3.3 Deleting DCN Communication Cables

In certain scenarios such as network adjustment, you can delete the DCN communication cable
that is not applicable.
Prerequisite
You must be an NM user with "NE operator" authority or higher.
Procedure
Step 1 On the Main Topology, right-click the cable and choose Delete from the shortcut menu.
Step 2 Click Yes in the Confirm dialog box that is displayed.
----End

5.4 Modifying the Service Configuration Data

You can modify the existing service configuration data according to the requirements.

5.4.1 Modifying SDH Services

To modify an SDH service, you can use the modification function of the U2000, or delete the
service and then create the cross-connection again.
5.4.2 Deleting SDH Services
You can delete an existing SDH service.
5.4.3 Deleting Ethernet Private Line Services
Ethernet private line services need to be deleted when the Ethernet boards that are configured
with the Ethernet private line services need to be deleted or when the service configuration is
incorrect.
5.4.4 Deleting EPLAN Services
EPLAN services need to be deleted when the Ethernet boards that are configured with the
EPLAN services need to be deleted or when the configuration of the EPLAN services is incorrect.
5.4.5 Deleting EVPLAN Services
EVPLAN services need to be deleted when the Ethernet boards that are configured with the
EVPLAN services need to be deleted or when the configuration of the EVPLAN services is
incorrect.
5.4.1 Modifying SDH Services
To modify an SDH service, you can use the modification function of the U2000, or delete the
service and then create the cross-connection again.
Prerequisite
You must be an NM user with "NE operator" authority or higher.
Issue 02 (2011-06-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
5 Modifying the Configuration Data
5-9

Hide quick links:

Advertisement

Table of Contents