4 Configuring Ethernet Services
3.
4-68
User
Paramete
r
Av
aila
ble
Res
our
ces
Av
aila
ble
Ti
me
slot
s
Configure the Ethernet private line services between user C1 and user C2 and between user
C1 and user C3.
l In the NE Explorer, select the EFS8 board and then choose Configuration > Ethernet
Service > Ethernet Line Service from the Function Tree.
l Click New on the lower-right pane to display the Create Ethernet Line Service
window. Set the following parameters and then click OK. The Operation Result dialog
box is displayed, indicating that the operation is successful. Click Close.
User
Parameter
User C1
Service
Type
←→user
C2
Service
Direction
Source Port
Source C-
VLAN (e.g.
1, 3-6)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
OptiX OSN 550 Multi-Service CPE Optical Transmission
Value in
Description
This
Example
VC4-4
Select VC4-4.
For the resources used by other boards, see
6.2 Requirements for Binding Paths with
VCTRUNKs on Ethernet
VC12-11
Ten VC-12s need to be bound. In this
to
example, the eleventh to the twentieth
VC12-20
VC-12s need to be selected in sequence.
Value in
Description
This
Example
EPL
The service between user C1 and C2 is a point-
to-point Ethernet private line service.
Bidirection
The service between user C1 and user C2 is a
al
bidirectional service.
PORT1
When creating the bidirectional Ethernet
service from a PORT to a VCTRUNK, it is
recommended that you use a specific PORT as
the source port. PORT1 is the external port
used by the service between user C1 and user
C2.
100
According to the plan, the VLAN ID is set to
100 for the Ethernet service between user C1
and user C2.
System
Configuration Guide
Boards.
Issue 02 (2011-06-30)

Hide quick links:

Advertisement

Table of Contents
loading