4.6.3 Configuration Process

Ethernet switching boards are required for creating EVPL services of different VLAN IDs on
NE1. In this way, the data of different users received from the same external port can be
differentiated. Ethernet transparent transmission boards are required for creating EPL
transparent transmission services on NE2 and NE4.
Prerequisite
You must be familiar with
Background Information
If the Ethernet boards in the actual application scenarios are different from the boards in this
example, you need to learn about the requirements for configuring specific boards.
l
l
Procedure
Step 1 Configure the EVPL services for user C1 on NE1.
1.
Issue 02 (2011-06-30)
4.3.2 Flow of Configuring EVPL
For the EVPL services supported by Ethernet switching boards, see
Capability of Ethernet
For the VCTRUNK binding requirements of Ethernet switching boards, see
Requirements for Binding Paths with VCTRUNKs on Ethernet
Set the attributes of the external port (PORT1 of the EFS8 board) used by the service of
user C1.
l In the NE Explorer, select the EFS8 board, and then choose Configuration > Ethernet
Interface Management > Ethernet Interface from the Function Tree.
l Select External Port.
l Click the Basic Attributes tab. After setting the parameters, click Apply.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
NE1
EVPL1
(PORT1←→
VCTRUNK1)
Bidirectional
PORT1
100
VCTRUNK1
100
Boards.
4 Configuring Ethernet Services
EVPL2
(PORT1←→VCTRUNK2)
PORT1
200
VCTRUNK2
200
Services.
6.1 Service Support
6.2
Boards.
4-63