7.35 Responding MP Type (Ethernet LT Test)

Description
The Responding MP Type (Ethernet LT Test) parameter specifies the type of the responding
maintenance point in each LT test.
Impact on the System
The system operation is not affected.
Values
Valid Values
MEP, MIP, Unknown
Configuration Guidelines
None.
Relationship with Other Parameters
The responding maintenance point must return the type, which is specified when this
maintenance point is created.

7.36 Hop Count (Ethernet LT Test)

Description
The Hop Count (Ethernet LT Test) parameter specifies the number of hops from the
maintenance source endpoint to an maintenance intermediate point, namely, the number of
responding intermediate points from the maintenance source point to a certain responding point.
As shown in
and MIP4 are the maintenance intermediate points. In this case, the number of hops from MEP1
to MEP2 is 5, and that from MEP1 to MIP3 is 3.
Issue 02 (2011-06-30)
Figure
7-3, MEP1 and MEP2 are the maintenance endpoints. MIP1, MIP2, MIP3