Huawei OptiX OSN 550 Configuration Manual page 116

Multi-service cpe optical transmission system
Table of Contents

Advertisement

3 Configuring SDH Services
3.
Step 3 Check whether the services are configured correctly. For details, see Verifying the Correctness
of the SDH Service Configuration.
3-34
Parameter
Value in
This
Example
Sink
1-5
Timeslot
Range(e.g.
1,3-6)
Activate
Yes
Immediately
Configure SDH services on the sink NE (NE1).
Parameter
Value in
This
Example
Level
VC12
Direction
Unidirection
al
Source Slot
1-SL1D-2
(SDH-2)
Source VC4
VC4-1
Source
1-5
Timeslot
Range(e.g.
1,3-6)
Sink VC4
3-SP3D
Sink
1-5
Timeslot
Range(e.g.
1,3-6)
Activate
Yes
Immediately
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
OptiX OSN 550 Multi-Service CPE Optical Transmission
Description
The total capacity of the services is 5xE1 according to
the plan. Hence, Sink Timeslot Range(e.g.1,3-6) is set
to 1-5.
-
Description
In this example, E1 services are configured. Hence,
Level of the E1 services is set to VC12.
In this example, the services are transmitted and received
on the same path. That is, the services are bidirectional
services. Hence, Direction of the services is set to
Bidirectional.
In this example, the SL1D board in slot 1 is configured
as the source line board. See
In this example, the service requires five VC-12s.
Source VC4 is set to VC4-1, because a VC-4 contains
63 VC-12s.
The total capacity of the services is 5xE1 according to
the plan. Hence, Source Timeslot Range(e.g.1,3-6) is
set to 1-5.
In this example, the SP3D board in slot 3 is configured
as the sink tributary board for the unidirectional services
from NE3 to NE1. See
Figure
The total capacity of the services is 5xE1 according to
the plan. Hence, Sink Timeslot Range(e.g.1,3-6) is set
to 1-5.
-
System
Configuration Guide
Figure
3-10.
3-10.
Issue 02 (2011-06-30)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents