Network Attributes; Table 4-37 Parameters For Configuring Flow Control Of An Ethernet Port - Huawei OptiX OSN 550 Configuration Manual

Multi-service cpe optical transmission system
Table of Contents

Advertisement

OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide

Table 4-37 Parameters for configuring flow control of an Ethernet port

Field
Port
Non-Autonegotiation
Flow Control Mode
Autonegotiation Flow
Control Mode

4.11.3 Network Attributes

This topic describes the parameters, such as port attribute and P port encapsulation format, which
are used for configuring network attributes of an Ethernet port.
Table 4-38
port.
Issue 02 (2011-06-30)
Value Range
PORTn
Disabled, Enable Symmetric
Flow Control, Send Only,
Receive Only
Default value: Disable
Disabled, Enable
Dissymmetric Flow Control,
Enable Symmetric Flow
Control, Enable Symmetric/
Dissymmetric Flow Control
Default value: Disabled
lists the parameters that are used for configuring network attributes of an Ethernet
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
4 Configuring Ethernet Services
Description
Displays all the available
MAC ports on an Ethernet
board.
Specifies the PORT port. The
letter n indicates the number of
the PORT port.
The Non-Autonegotiation
Flow Control Mode
(Ethernet Port Attribute)
specifies the flow control
mode adopted when an
Ethernet port works in non-
auto-negotiation mode.
You can click
7.3 Non-
Autonegotiation Flow
Control Mode (Ethernet
Port Attribute)
to display the
detailed information.
The Autonegotiation Flow
Control Mode (Ethernet
Port Attribute) specifies the
flow control mode adopted
when an Ethernet port works in
auto-negotiation mode.
You can click
7.4
Autonegotiation Flow
Control Mode (Ethernet
Port Attribute)
to display the
detailed information.
4-133

Hide quick links:

Advertisement

Table of Contents
loading