Clock Source Threshold - Huawei OptiX OSN 550 Configuration Manual

Multi-service cpe optical transmission system
Table of Contents

Advertisement

7 List of Parameters

7.118 Clock Source Threshold

Description
The Clock Source Threshold parameter indicates the lower quality threshold of 2M external
clock source. When the clock quality level of the external clock source that is selected from the
2M phase-locked source priority table is inferior to the threshold, the 2M phase-locked source
becomes invalid, and the action specified for 2M phase-locked source failure is invoked to
control the external clock source output.
Impact on the System
The system running is not affected.
Values
Value Range
No Threshold Value, G.813
SETS Signal, G.812 Lock Clock
Signal, G.812 Transit Clock
Signal, G.811 Clock Signal
The following table lists the description of each value.
Value
No Threshold Value
G.813 SETS Signal
G.812 Lock Clock Signal
G.812 Transit Clock Signal
G.811 Clock Signal
Configuration Guidelines
In actual application, the output quality threshold of external clock source should be determined
according to the quality information about the NE clock and the opposite NE.
Relationship with Other Parameters
None.
7-96
OptiX OSN 550 Multi-Service CPE Optical Transmission
Default Value
No Threshold Value
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Description
Threshold disabled
Indicates that the lower threshold is not inferior to the
G.813 SETS signal.
Indicates that the lower threshold is not inferior to the
G.812 lock clock signal.
Indicates that the lower threshold is not inferior to the
G.812 transit clock signal.
Indicates that the lower threshold is not inferior to the
G.811 clock signal.
System