Field
External Clock Output
Timeslot
External Source Output
Threshold
2M Phase-Locked Source
Fail Condition
2-26
OptiX OSN 550 Multi-Service CPE Optical Transmission
Value Range
SA4, SA5, SA6, SA7, SA8,
All versions
Default value: All versions
Threshold Disabled, Not
Inferior to G.813 SETS
Signal, Not Inferior to G.812
Local Clock Signal, Not
Inferior to G.812 Transit
Clock Signal, Not Inferior to
G.811 Clock Signal
Default value: Threshold
Disabled
No Failure Condition, AIS,
LOF, AIS OR LOF
Default value: No Failure
Condition
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
System
Configuration Guide
Description
The External Clock Output
Timeslot parameter is used
to set the output timeslot for
the S1 byte of the external
clock source. The external
clock source transmits the S1
overhead byte through
certain timeslots. After
starting the SSM protocol,
make sure that the timeslot
for receiving the S1 byte is
consistent with the timeslot
for transmitting the S1 byte
so that the S1 byte can be
received correctly.
You can click
7.114
External Clock Output
Timeslot
to display the
detailed information.
The External Source
Output Threshold
parameter is used to set the
output quality threshold of
the external clock source.
When the output quality of
the external clock source is
inferior to the threshold, the
action specified for 2M
phase-locked source failure
is invoked to control the
external clock source output.
You can click
7.115
External Source Output
Threshold
to display the
detailed information.
The 2M Phase-Locked
Source Fail Condition
parameter is used to set the
failure condition of the 2M
phase-locked source.
You can click
7.116 2M
Phase-Locked Source Fail
Condition
to display the
detailed information.