7 List of Parameters
Values
Value Range
Enabled, Disabled
The following table provides the description of each value.
Value
Enabled
Disabled
Configuration Guidelines
Set this parameter according to the actual requirement of the user. Set this parameter to
Enabled if the traffic on a port needs to be monitored.

7.14 Port Traffic Threshold Time Window(Min)

Description
The Port Traffic Threshold Time Window(Min) parameter specifies the duration for a
VCTRUNK or a IP port to monitor the traffic after the zero traffic monitoring function of the
port is enabled.
Impact on the System
If the value of this parameter is too large, the port may fail to report the zero traffic alarm. If the
value of this parameter is too small, the jitter due to the zero traffic alarm may occur on the port.
Values
Board Name
EFS8
Configuration Guidelines
The user can set this parameter according to the actual service requirement.
7-16
OptiX OSN 550 Multi-Service CPE Optical Transmission
Default Value
Disabled
Description
The zero traffic monitoring function is enabled on the port.
The zero traffic monitoring function is disabled on the port.
Value Range
0-30
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Default Value
Unit
0
min
Issue 02 (2011-06-30)