Error Frame Period Window(Frames) - Huawei OptiX OSN 550 Configuration Manual

Multi-service cpe optical transmission system
Table of Contents

Advertisement

7 List of Parameters
Values
Valid Values
1-4294967295 (in step length of 1)
Configuration Guidelines
If higher link performance is required, set the threshold to a lower value. Otherwise, set the
threshold to a higher value.
Make sure that the value of Error Frame Monitor Threshold(Entries) is not greater than the
maximum number of frames received at the port within the time specified in Error Frame
Monitor Window (ms).
Relationship with Other Parameters
To set Error Frame Monitor Threshold(Entries), set Error Frame Monitor Window
(ms). Moreover, set Port Rate. For details, refer to the description of the Error Frame Period
Window(Frames)parameter.

7.43 Error Frame Period Window(Frames)

Description
The Error Frame Period Window(Frames) parameter specifies the received N frames in which
the number of error frames reach the specified upper threshold. In this case, a link event alarm
is reported.
Impact on the System
After you set the Error Frame Period Window(Frames) and Error Frame Period Threshold
(Frames) parameters, a link event alarm is reported if the number of error frames received within
a certain period reaches the specified upper threshold.
Values
Valid Values
Maxpps/10-Maxpps*60, in step length
of 1
Configuration Guidelines
Set the value according to the actual data frame transmission rate and the frames. If the data
transmission rate is high, set this parameter to a higher value. Otherwise, set this parameter to a
lower value.
7-40
OptiX OSN 550 Multi-Service CPE Optical Transmission
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Default Value
2
Default Value
Maxpps
System
Configuration Guide
Unit
Frame
Unit
Frame
Issue 02 (2011-06-30)