Min Members - Transmit Direction - Huawei OptiX OSN 550 Configuration Manual

Multi-service cpe optical transmission system
Table of Contents

Advertisement

OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
member has excessive B3 or BIP bit errors, the LCAS protocol regards that this member fails
and deletes it from the available members. If this parameter is set to Disabled, the LCAS protocol
does not monitor the status of the B3 or BIP bit errors of a VCTRUNK member.
Impact on the System
The system running is not affected.
Values
Value Range
Enabled, Disabled
Configuration Guidelines
You can set whether to enable the TSD as required.
Relationship with Other Parameters
This parameter is valid only when Enabling LCAS is set to Enabled.

7.89 Min Members - Transmit Direction

Description
When the LCAS is enabled, the LCAS_PLCT alarm is reported if certain members in the transmit
direction fail and the number of valid members is smaller than a certain value. The Min
Members - Transmit Direction parameter specifies the certain number of the valid members
in the transmit direction.
Impact on the System
When the LCAS is enabled, failure of certain paths does not affect the service in the case of
sufficient bandwidths. The user can set this parameter to enable the reporting of the LCAS_PLCT
alarm only when the number of the valid members in the transmit direction is smaller than a
certain value.
Values
Value Range
2-256
Configuration Guidelines
Set this parameter according to the actual requirement of the user.
Issue 02 (2011-06-30)
Default Value
256
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
7 List of Parameters
Default Value
Disabled
7-73