Impact on the System
All the equipment on the service access point and in the intermediate network should use the
same LPT bearer mode. Otherwise, the LPT function cannot work normally.
Values
Value Range
GFP(HUAWEI), Ethernet, GFP(CSF)
The following table provides the description of each value.
Value
GFP(HUAWEI)
Ethernet
GFP(CSF)
Configuration Guidelines
Set this parameter according to the actual requirement of the user. Ensure that the configurations
of the two interconnected ports are consistent.

7.92 Port-Type Port Hold-Off Time (ms)

Description
The Port-Type Port Hold-Off Time (ms) parameter specifies the interval for the PORT to
transmit the LPT fault information after it receives the information.
Impact on the System
The greater the hold-off time of the PORT, the slower is the transmission of fault information
between networks.
Values
Value Range
0-10000 (in step length of 100)
Configuration Guidelines
Set this parameter according to the actual requirement of the user.
Issue 02 (2011-06-30)
Description
Indicates the frame format specially used by Huawei.
Indicates the Ethernet frame format.
Indicates the standard CSF frame format.
Default Value
0
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Default Value
GFP(HUAWEI)
Unit
ms