Ethernet Port Configuration Parameters - Huawei OptiX OSN 550 Configuration Manual

Multi-service cpe optical transmission system
Table of Contents

Advertisement

4 Configuring Ethernet Services
Step 2 Configure the EPL services on NE2 and NE4.
NOTE
Step 3 Enable the performance monitoring function of the NEs. For details, see Setting Performance
Monitoring Parameters of an NE.
Step 4 Back up the configuration data of the NEs. For details, see Backing Up the NE Database to the
SCB Board.
----End
Relevant Task
If the services are configured incorrectly and thus need to be deleted, see Deleting SDH Services.

4.11 Ethernet Port Configuration Parameters

Before configuring an Ethernet service, you need to configure the corresponding Ethernet ports.
4.11.1 Basic Attributes
This topic describes the parameters, such as the port attribute, port enabling status, and maximum
frame length, that are used for configuring the basic attributes of an Ethernet port.
4.11.2 Flow Control
This topic describes the parameters, such as autonegotiation and non-autonegotiation, which are
used for configuring flow control function of an Ethernet port.
4.11.3 Network Attributes
This topic describes the parameters, such as port attribute and P port encapsulation format, which
are used for configuring network attributes of an Ethernet port.
4.11.4 Advanced Attributes
This topic describes the parameters, such as the loop detection, loop port shutdown, and traffic
threshold (Mbit/s), which are used for configuring the advanced attributes of an Ethernet port.
4-130
User
Paramete
r
Sink VC4
Sink
Timeslot
Range(e.g.
1,3-6)
Activate
Immediatel
y
The Ethernet services of NE2 and NE4 are point-to-point transparent transmission services. See
Configuring EPL Services on an Ethernet Transparent Transmission Board
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
OptiX OSN 550 Multi-Service CPE Optical Transmission
Value in
Description
This
Example
VC4-1
In this example, VC4-1 is specified as the
VC-4 timeslot of the Ethernet service on the
line board.
1-30
The value range of the sink timeslots can be
the same as or different from the value
range of the source timeslots. The number
of source timeslots must be, however, the
same as the number of sink timeslots.
Yes
-
System
Configuration Guide
4.4
to set the parameters.
Issue 02 (2011-06-30)