Configuring The Multiplex Section Protection - Huawei OptiX OSN 550 Configuration Manual

Multi-service cpe optical transmission system
Table of Contents

Advertisement

OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
Field
WTR Time (s)
Hold-Off Time (100 ms)
Source Board
Sink Board
Source VC4
Sink VC4
Source Timeslot Range(eg.1,
3-6)

3.11.2 Configuring the Multiplex Section Protection

You need to set the necessary parameters when configuring the multiplex section protection
(MSP).
Table 3-2
Issue 02 (2011-06-30)
Value
Example: 600
0 to 100
Default: 0
Example: 1-SL1D-1
(SDH-1)
Example: 3-SP3D
Example: VC4-1
-
Example: 1-5
lists the parameters for configuring the MSP.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3 Configuring SDH Services
Description
Specifies the wait-to-restore
(WTR) time of the NE.
When the time after the
former working channel is
restored to normal reaches the
set WTR time, a revertive
switching occurs. This field is
available only when
Revertive Mode is set to
Revertive.
Specifies the hold-off time of
the NE.
If Hold-Off Time (100 ms) is
set to 0, you do not need to set
a specific hold-off time.
Displays the slot ID, board
name, port number, and port
name at the source end.
Displays the slot ID, board
name, port number, and port
name at the sink end.
Specifies the VC-4 timeslot at
the source end.
One VC-4 timeslot can
contain a maximum of 63
VC-12 timeslots.
Specifies the VC-4 timeslot at
the sink end.
Specifies the timeslot range at
the source end.
3-69