Prerequisite
l
l
Procedure
Step 1 Double-click the unconfigured NE on the Main Topology. Then, the NE Configuration
Wizard dialog box is displayed.
Step 2 Select Manual Configuration and click Next. Then, the Confirm dialog box is displayed,
indicating that manual configuration clears the data on the NE.
Step 3 Click OK. Then, the Confirm dialog box is displayed, indicating that manual configuration
interrupts the service on the NE.
Step 4 Click OK. Then, the Set NE Attribute dialog box is displayed.
Step 5 Set NE Name, Equipment Type, NE Remarks, and Shelf Type and then click Next. The NE
slot layout window is displayed.
Step 6 Optional: Click Query Logical Information to query the logical boards of the NE.
Step 7 Optional: Click Query Physical Information to query the physical boards of the NE.
NOTE
Step 8 Right-click the slot to which you need to add a board. Click Next. Then, the Send
Configuration window is displayed.
Step 9 Select Verify and Run according to the requirements and click Finish.
NOTE
----End
Issue 02 (2011-06-30)
The NE must be created successfully.
You must be an NM user with "NE operator" authority or higher.
The Query Logical Information and Query Physical Information operations cannot be performed for
a preconfigured NE.
Verification is to run the verification command. Click Finish to deliver the configuration data to the NE,
thus completing the basic configuration of the NEs. After the successful verification, the NEs start to work
normally.