Hold-Off Time (Ms) (Lcas) - Huawei OptiX OSN 550 Configuration Manual

Multi-service cpe optical transmission system
Table of Contents

Advertisement

OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
Values
Value Range
Huawei Mode, Standard
Mode
The following table lists the description of each value.
Value
Huawei Mode
Standard Mode
Configuration Guidelines
To set the LCAS mode, follow the principles:
l
l
Relationship with Other Parameters
None.

7.86 Hold-Off Time (ms) (LCAS)

Description
The Hold-Off Time (ms)(LCAS) parameter is also called HO Procedure Timer Duration. It
specifies HO Procedure Timer Duration of the LCAS protocol. If the LCAS coexists with
another network-level protection scheme (for example, MSP or SNCP), you can set this
parameter to postpone the LCAS switching.
Impact on the System
The LCAS switching tiime is affected.
For example, if both the MSP and the LCAS are available in a network, set the LCAS hold off
time to 2000 ms. If the network fails, only the MSP switching occurs, but the LCAS switching
does not occur.
Issue 02 (2011-06-30)
If the interconnected equipment at the two ends are Huawei equipment, select Huawei
Mode.
If Huawei equipment is interconnected to a third-party equipment, set the interconnected
equipment to the same mode according to the mode supported by the third-party equipment.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Default Value
Huawei Mode
Description
Inverts the RS_Ack message, and then transmits the MST
message.
Transmits the MST message, and then Inverts the RS_Ack
message.
7 List of Parameters