Huawei OptiX OSN 550 Configuration Manual page 357

Multi-service cpe optical transmission system
Table of Contents

Advertisement

OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
Values
Board Name
EFS8
The following table lists the description of each value.
Value
Add S-VLAN
Translate S-VLAN
Transparently transmit S-
VLAN
Transparently transmit C-
VLAN
Transparently Transmit S-
VLAN and C-VLAN
Strip S-VLAN
Issue 02 (2011-06-30)
Valid Values
l For bidirectional services, the options are as
follows:
– Add S-VLAN
– Transparently Transmit C-VLAN
– Transparently Transmit S-VLAN
– Transparently Transmit S-VLAN and C-
VLAN
– Translate S-VLAN
l For unidirectional services, the options are as
follows:
– Add S-VLAN
– Transparently Transmit C-VLAN
– Transparently Transmit S-VLAN
– Transparently Transmit S-VLAN and C-
VLAN
– Translate S-VLAN
– Strip S-VLAN
Description
Indicates that the one layer of S-VLAN label is added to the
processed packets in the service.
If the source S-VLAN labels of the packets processed in the
service are translated into the sink S-VLAN labels, the source
S-VLAN label must be different from the sink S-VLAN label.
Forwards the service packets according to the port or S-VLAN.
After the packets are processed in the service, the S-VLAN
labels in the packets are not changed.
Forwards the service packets according to the port or C-VLAN.
After the packets are processed in the service, the C-VLAN
labels in the packet are not changed.
Indicates that the Transparently transmit C-VLAN and
Transparently transmit S-VLAN labels are added to the packets
processed in the service.
Strips the S-VLAN label.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
7 List of Parameters
Default Value
Add S-VLAN
7-27

Hide quick links: