Table 2-4 Parameters For Configuring The 2M Phase-Locked Source Attributes Of An External Clock - Huawei OptiX OSN 550 Configuration Manual

Multi-service cpe optical transmission system
Table of Contents

Advertisement

OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
Field
Clock Source Threshold
Table 2-4
of an external clock.

Table 2-4 Parameters for configuring the 2M phase-locked source attributes of an external clock

Field
2M Phase-Locked Source
Number
External Clock Output
Switch
External Clock Output Mode 2 MHz, 2 Mbit/s
Issue 02 (2011-06-30)
Value Range
No Threshold Value, G.813
SETS Signal, G.812 Lock
Clock Signal, G.812 Transit
Clock Signal, G.811 Clock
Signal
Default value: No Threshold
Value
lists the parameters that are used for configuring the 2M phase-locked source attributes
Value Range
For example: NE
(9-5595)-2M phase-locked
source 1
Open, Close
Default value: 2 Mbit/s
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2 Creating the Network
Description
The Clock Source
Threshold parameter
indicates the lower quality
threshold of 2M external
clock source. When the clock
quality level of the external
clock source that is selected
from the 2M phase-locked
source priority table is
inferior to the threshold, the
2M phase-locked source
becomes invalid, and the
action specified for 2M
phase-locked source failure
is invoked to control the
external clock source output.
You can click
7.118 Clock
Source Threshold
to display
the detailed information.
Description
Displays the number of the
external clock source output
of the NE.
Specifies the output switch of
the external clock source.
The External Clock Output
Mode parameter is used to
set the output mode of the
external clock source to 2
Mbit/s or 2 MHz.
You can click
7.113
External Clock Output
Mode
to display the detailed
information.
2-25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents