3 Configuring SDH Services
Step 4 Check whether the services are configured correctly. For details, see Verifying the Correctness
of the SDH Service Configuration.
Step 5 Enable the performance monitoring function of the NEs. For details, see Setting Performance
Monitoring Parameters of an NE.
Step 6 Back up the configuration data of the NEs. For details, see Backing Up the NE Database to the
SCB Board.
----End
Relevant Task
If the services are configured incorrectly and thus need to be deleted, see Deleting SDH Services.

3.7.4 End-to-End Configuration Process

The configuration of two-fiber bidirectional MSP services is independent of the configuration
of a protection subnet. To configure two-fiber bidirectional MSP services, configure SDH
services from the tributary board to the line board on the source and sink NEs and configure
pass-through services on the intermediate NEs if a protection subnet has already been configured.
The following part describes how to configure two-fiber bidirectional MSP services in end-to-
end mode.
3-42
Parameter
Value in
This
Example
Source VC4
VC4-1
Source
1-5
Timeslot
Range(e.g.
1,3-6)
Sink Slot
1-SL4D-1
(SDH-1)
Sink VC4
VC4-1
Sink
1-5
Timeslot
Range(e.g.
1,3-6)
Activate
Yes
Immediately
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
OptiX OSN 550 Multi-Service CPE Optical Transmission
Description
In this example, the services require five VC-12s.
Source VC4 is set to VC4-1, because a VC-4 contains
63 VC-12s.
In this example, the total capacity of the services is 5xE1
according to the plan. The service level is VC12. Hence,
Source Timeslot Range(e.g.1,3-6) is set to 1-5. See
Figure
3-12.
In this example, the SL4D board in slot 1 is configured
as the sink line board. See
different sink boards depending on the actual situation.
In this example, the services require five VC-12s. Sink
VC4 is set to VC4-1, because a VC-4 contains 63
VC-12s.
In this example, the total capacity of the services is 5xE1
according to the plan. The service level is VC12. Hence,
Sink Timeslot Range(e.g.1,3-6) is set to 1-5. See
Figure
3-12.
-
System
Configuration Guide
Figure
3-12. You can select
Issue 02 (2011-06-30)