End-To-End Configuration Process - Huawei OptiX OSN 550 Configuration Manual

Multi-service cpe optical transmission system
Table of Contents

Advertisement

OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
Step 4 Enable the performance monitoring function of the NEs. For details, see Setting Performance
Monitoring Parameters of an NE.
Step 5 Back up the configuration data of the NEs. For details, see Backing Up the NE Database to the
SCB Board.
----End
Relevant Task
If the services are configured incorrectly and need to be deleted, see Deleting SDH Services.

3.6.4 End-to-End Configuration Process

This topic describes how to configure two-fiber unidirectional MSP services.
Prerequisite
l
l
l
l
Background Information
In end-to-end mode, configuration of two-fiber unidirectional MSP services is similar to
configuration of two-fiber bidirectional MSP services. The only difference is that you set
Direction to Unidirectional for two-fiber unidirectional MSP services and set Direction to
Bidirectional for two-fiber bidirectional MSP services.
Procedure
Step 1 Choose Service > SDH Trail > Create SDH Trail from the Main Menu.
Step 2 Create a VC4 server trail.
1.
2.
Issue 02 (2011-06-30)
The physical network topology must be set up.
NEs, boards, and fibers must be successfully created on the U2000.
A linear MSP subnet must be created and must be the same as the actual topology. For
details about how to create a protection subnet, see
Subnet.
The operator must understand the information provided in
Allocation.
Set associated parameters as follows. Set Direction to Unidirectional and Level to VC4
Server Trail, and take default values for other parameters.
Double-click the source NE (NE1) and sink NE (NE3) on the right of the Main Topology
and click Apply. Then, click Close in the Operation Result dialog box that is displayed,
if the operation is successful. A unidirectional VC4 server trail is set up from NE1 to NE3.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3 Configuring SDH Services
2.6.3 Creating an MS Ring Protection
3.6.2 Signal Flow and Timeslot
3-35