System - ABB +N5600 Firmware Instructions

Single drive
Table of Contents

Advertisement

No.
Name/Value
95.36
Supply voltage low
0.0...1000.0 V
95.37
Supply voltage high
0.0...1000.0 V
95.40
Transformation ratio
0.000...100.000
96

96 System

96.01
Language
Not selected
English
Deutsch
Italiano
Español
Portugues
Nederlands
Français
Dansk
Suomi
Svenska
Russki
Polski
Czech
Description
Defines the low limit for the supply voltage allowed for normal
operation.
This parameter is active only when
voltage
is enabled.
Note: This is an expert level parameter and should not be
adjusted without appropriate skills.
WARNING! An incorrect setting may cause the motor
to rush uncontrollably, or the brake chopper or resistor
to overload.
Supply voltage low.
Defines the high limit for the supply voltage allowed for
normal operation.
This parameter is active only when
voltage
is enabled.
Note: This is an expert level parameter and should not be
adjusted without appropriate skills.
WARNING! An incorrect setting may cause the motor
to rush uncontrollably, or the brake chopper or resistor
to overload.
Supply voltage high.
Defines transformation ratio.
Transformation ratio.
Language selection; access levels; macro selection;
parameter save and restore; control unit reboot; user
parameter sets; unit selection; data logger triggering;
parameter checksum calculation; user lock.
Selects the language of the parameter interface and other
displayed information when viewed on the control panel.
Notes:
• Not all languages listed below are necessarily supported.
• This parameter does not affect the languages visible in the
Drive composer PC tool. (Those are specified under View
– Settings.)
None.
English.
German.
Italian.
Spanish.
Portuguese.
Dutch.
French.
Danish.
Finnish.
Swedish.
Russian.
Polish.
Czech.
Parameters 479
95.35 Adjustable supply
95.35 Adjustable supply
Def/FbEq16
0.0
0.0
1.000
-
0
1033
1031
1040
3082
2070
1043
1036
1030
1035
1053
1049
1045
1029

Hide quick links: