Fba B Data In - ABB +N5600 Firmware Instructions

Single drive
Table of Contents

Advertisement

384 Parameters
No.
Name/Value
Refresh
54.28
FBA B par table ver
54.29
FBA B drive type
code
0...65535
54.30
FBA B mapping file
ver
0...65535
54.31
D2FBA B comm
status
Not configured
Initializing
Time out
Configuration error
Off-line
On-line
Reset
54.32
FBA B comm SW
ver
54.33
FBA B appl SW ver
55

55 FBA B data in

55.01
FBA B data in1
None
CW 16bit
Ref1 16bit
Ref2 16bit
Description
Refreshing.
Displays the parameter table revision of the fieldbus adapter
module mapping file (stored in the memory of the drive).
In format axyz, where ax = major table revision number; yz =
minor table revision number.
This parameter is read-only.
Parameter table revision of adapter module.
Displays the drive type code in the fieldbus adapter module
mapping file (stored in the memory of the drive).
This parameter is read-only.
Drive type code stored in the mapping file.
Displays the fieldbus adapter module mapping file revision
stored in the memory of the drive in decimal format.
This parameter is read-only.
Mapping file revision.
Displays the status of the fieldbus adapter module
communication.
Adapter is not configured.
Adapter is initializing.
A timeout has occurred in the communication between the
adapter and the drive.
Adapter configuration error: mapping file not found in the file
system of the drive, or mapping file upload has failed more
than three times.
Fieldbus communication is off-line.
Fieldbus communication is on-line, or fieldbus adapter has
been configured not to detect a communication break. For
more information, see the documentation of the fieldbus
adapter.
Adapter is performing a hardware reset.
Displays the patch and build versions of the adapter module
firmware in format xxyy, where xx = patch version number, yy
= build version number.
Example: C802 = 200.02 (patch version 200, build version 2).
Patch and build versions of adapter module firmware.
Displays the major and minor versions of the adapter module
firmware in format xyy, where x = major revision number, yy =
minor revision number.
Example: 300 = 3.00 (major version 3, minor version 00).
Major and minor versions of adapter module firmware.
Selection of data to be transferred from drive to fieldbus
controller through fieldbus adapter B.
Parameters
55.01...55.12
the drive to the fieldbus controller through fieldbus adapter B.
None.
Control Word (16 bits)
Reference REF1 (16 bits)
Reference REF2 (16 bits)
select data to be transferred from
Def/FbEq16
1
-
-
-
1 = 1
-
1 = 1
-
0
1
2
3
4
5
6
-
-
None
0
1
2
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents