Operation Mode - ABB +N5600 Firmware Instructions

Single drive
Table of Contents

Advertisement

No.
Name/Value
16.83
AO1 out at AO1 src
max
16.86
AO2 actual value
16.87
AO2 source
16.88
AO2 force data
16.89
AO2 filter time
16.90
AO2 source min
16.91
AO2 source max
16.92
AO2 out at AO2 src
min
16.93
AO2 out at AO2 src
max
19

19 Operation mode

19.01
Actual operation
mode
Zero
Speed
Torque
Min
Max
Add
Scalar (Hz)
Scalar (rpm)
Forced magn.
19.11
Ext1/Ext2 selection
EXT1
EXT2
FBA A MCW bit 11
DI1
Description
(Visible when
16.01 Module 3 type
See parameter
14.83 AO1 out at AO1 src
(Visible when
16.01 Module 3 type
See parameter
14.86 AO2 actual
(Visible when
16.01 Module 3 type
See parameter
14.87 AO2
(Visible when
16.01 Module 3 type
See parameter
14.88 AO2 force
(Visible when
16.01 Module 3 type
See parameter
14.89 AO2 filter
(Visible when
16.01 Module 3 type
See parameter
14.90 AO2 source
(Visible when
16.01 Module 3 type
See parameter
14.91 AO2 source
(Visible when
16.01 Module 3 type
See parameter
14.92 AO2 out at AO2 src
(Visible when
16.01 Module 3 type
See parameter
14.93 AO2 out at AO2 src
Selection of local and external control location sources and
operating modes.
See also section
Operating modes of the drive
Displays the operating mode currently used.
See parameters 19.11...19.14.
This parameter is read-only.
None.
Speed control (in DTC motor control mode).
Torque control (in DTC motor control mode).
The torque selector is comparing the output of the speed
controller
(25.01 Torque reference speed
reference
(26.74 Torque ref ramp
two is used.
The torque selector is comparing the output of the speed
controller
(25.01 Torque reference speed
reference
(26.74 Torque ref ramp
two is used.
The speed controller output is added to the torque reference.
Frequency control in scalar motor control mode.
Speed control in scalar motor control mode.
Motor is in magnetizing mode.
Selects the source for external control location EXT1/EXT2
selection.
0 = EXT1
1 = EXT2
EXT1 (permanently selected).
EXT2 (permanently selected).
Control word bit 11 received through fieldbus interface A.
Digital input DI1
(10.02 DI delayed
=
FIO-11
or FAIO-01)
max.
= FAIO-01)
value.
= FAIO-01)
source.
= FAIO-01)
data.
= FAIO-01)
time.
= FAIO-01)
min.
= FAIO-01)
max.
= FAIO-01)
min.
= FAIO-01)
max.
(page 26).
control) and torque
out) and the smaller of the
control) and torque
out) and the greater of the
status, bit 0).
Parameters 231
Def/FbEq16
10.000 mA
-
Zero
0.000 mA
0.100 s
0.0
100.0
0.000 mA
10.000 mA
-
1
2
3
4
5
6
10
11
20
EXT1
0
1
2