ABB +N5600 Firmware Instructions page 89

Single drive
Table of Contents

Advertisement

Pos counter init cmd
activated. A successful initialization is indicated by bit 4 of
Any subsequent initialization of the counter must first be enabled by
counter init
ready. To define a time window for initializations,
counter initialization
active fault in the drive will also prevent counter initialization.
Encoder error handling
When an encoder is used for load feedback, the action taken in case of an encoder
error is specified by
calculation will continue smoothly using estimated motor position. If the encoder
recovers from the error, the calculation will smoothly switch back to encoder
feedback. The load position signals (90.04,
updated all the time, but bit 6 of
potentially inaccurate position data. In addition, bit 4 of
next stop as a recommendation to reinitialize the position counter.
Parameter
90.60 Pos counter error and boot action
calculation resumes from the previous value over an encoder error or control unit
reboot. By default, bit 4 of
indicating that reinitialization is needed. With
value, the position values are retained over an error or reboot; bit 6 of
however to indicate that an error occurred.
Note: With a multiturn absolute encoder, bit 6 of
the drive if the encoder has recovered from the error; bit 4 is not cleared. The status
of the position counter is retained over a control unit reboot, after which position
calculation resumes from the absolute position given by the encoder, taking into
account the initial position specified by 90.58.
WARNING! If the drive is in stopped state when an encoder error occurs, or if
the drive is not powered, parameters 90.04, 90.05,
updated because no movement of the load can be detected. When using previous
position values
(90.60 Pos counter error and boot action
previous
value), be aware that the position data is unreliable if the load is able to
move.
Reading/writing position counter values through fieldbus
The parameters of the position counter function, such as
int
and
90.58 Pos counter init value
system in the following formats:
16-bit integer (if 16 bits are sufficient for the application)
32-bit integer (can be accessed as two consequent 16-bit words).
source, such as a proximity switch connected to a digital input, is
can be used to inhibit the signal from the proximity switch. An
90.55 Load feedback
90.35 Pos counter status
90.35 Pos counter status
int, can be accessed from an upper-level control
90.35 Pos counter
fault. If the parameter is set to Warning, the
90.05
and 90.07) will continue to be
will be set to indicate
90.35
defines whether position
is cleared after an error,
90.60
set to
Continue from previous
90.35
is cleared at the next stop of
90.07
is set to
90.07 Load position scaled
Program features 89
status.
90.69 Reset pos
90.68 Disable pos
will be cleared upon the
90.35
is set
and
90.35
are not
Continue from