ABB +N5600 Firmware Instructions page 407

Single drive
Table of Contents

Advertisement

No.
Name/Value
61.26
M/F data 2 value
0...65535
61.27
M/F data 3 value
0...65535
61.45
Data set 2 data 1
selection
None
CW 16bit
SW 16bit
Act1 16bit
Act2 16bit
Other
61.46
Data set 2 data 2
selection
61.47
Data set 2 data 3
selection
...
...
61.50
Data set 4 data 3
selection
61.51
Data set 11 data 1
selection
None
Description
Displays the data to be sent onto the master/follower link as
word 2 as an integer.
If no data has been preselected by
selection, the value to be sent can be written directly into this
parameter.
Data to be sent as word 2 in master/follower communication.
Displays the data to be sent onto the master/follower link as
word 3 as an integer.
If no data has been preselected by
selection, the value to be sent can be written directly into this
parameter.
Data to be sent as word 3 in master/follower communication.
Parameters
61.45...61.50
sets 2 and 4 to the external controller. These data sets are
used in ModuleBus communication with a "standard drive"
(60.50 DDCS controller drive type
Parameters
61.95...61.100
external controller. If no data has been preselected, the value
to be sent can be written directly into these parameters.
For example, this parameter preselects the data for word 1 of
data set 2. Parameter
61.95 Data set 2 data 1 value
the selected data in integer format. If no data is preselected,
the value to be sent can be written directly into parameter
61.95.
None.
Control Word (16 bits)
Status Word (16 bits)
Actual value ACT1 (16 bits)
Actual value ACT2 (16 bits)
Source selection (see
Terms and abbreviations
Preselects the data to be sent as word 2 of data set 2 to the
external controller.
See also parameter
61.96 Data set 2 data 2
For the selections, see parameter
selection.
See parameter
61.45 Data set 2 data 1
...
See parameter
61.45 Data set 2 data 1
Parameters
61.51...61.74
sets 11, 13, 15, 17, 19, 21, 23 and 25 to the external
controller.
Parameters
61.101...61.124
external controller. If no data has been preselected, the value
to be sent can be written directly into these parameters.
For example, this parameter preselects the data for word 1 of
data set 11. Parameter
61.101 Data set 11 data 1 value
displays the selected data in integer format. If no data is
preselected, the value to be sent can be written directly into
parameter 61.101.
None.
61.02 M/F data 2
61.03 M/F data 3
preselect data to be sent in data
=
ABB standard
display the data to be sent to the
on page 148). -
value.
61.45 Data set 2 data 1
selection.
selection.
preselect data to be sent in data
display the data to be sent to the
Parameters 407
Def/FbEq16
0
0
None
drive).
displays
0
1
4
5
6
None
None
...
None
None
0