312 Parameters
No.
Name/Value
31.120 LSU earth fault
No action
Warning
Fault
31.121 LSU supply phase
loss
No action
Fault
32

32 Supervision

32.01
Supervision status
Bit
Name
0
Supervision 1 active
1
Supervision 2 active
2
Supervision 3 active
3...15
Reserved
0000...0111b
32.05
Supervision 1
function
Disabled
Low
High
Abs low
Abs high
Both
Abs both
Description
(Only visible when IGBT supply unit control activated by
95.20)
Selects how the supply unit reacts when an earth fault or
current unbalance is detected.
No action taken.
The supply unit generates an AE02 Earth leakage warning.
The supply unit trips on fault 2E01 Earth leakage.
(Only visible when IGBT supply unit control activated by
95.20)
Selects how the supply unit reacts when a supply phase loss
is detected.
No action taken.
The supply unit trips on fault 3E00 Input phase loss.
Configuration of signal supervision functions 1...3.
Three values can be chosen to be monitored; a warning or
fault is generated whenever predefined limits are exceeded.
See also section
Signal supervision
Signal supervision status word.
Indicates whether the values monitored by the signal
supervision functions are within or outside their respective
limits.
Note: This word is independent of the drive actions defined
by parameters 32.06,
32.16
Description
1 = Signal selected by
1 = Signal selected by
1 = Signal selected by
Signal supervision status word.
Selects the mode of signal supervision function 1. Determines
how the monitored signal (see parameter 32.07) is compared
to its lower and upper limits
The action to be taken when the condition is fulfilled is
selected by 32.06.
Signal supervision 1 not in use.
Action is taken whenever the signal falls below its lower limit.
Action is taken whenever the signal rises above its upper
limit.
Action is taken whenever the absolute value of the signal falls
below its (absolute) lower limit.
Action is taken whenever the absolute value of the signal
rises above its (absolute) upper limit.
Action is taken whenever the signal falls below its low limit or
rises above its high limit.
Action is taken whenever the absolute value of the signal falls
below its (absolute) low limit or rises above its (absolute) high
limit.
(page 123).
and 32.26.
32.07
is outside its limits.
32.17
is outside its limits.
32.27
is outside its limits.
(32.09
and
32.10
respectively).
Def/FbEq16
Fault
0
1
2
Fault
0
1
0000b
1 = 1
Disabled
0
1
2
3
4
5
6