334 Parameters
No.
Name/Value
35.104 DOL starter
feedback delay
0...42949673 s
35.105 DOL starter status
word
Bit
Name
0
Start command
1
Delayed start
command
2
DOL feedback
3
DOL fault (-1)
4...15
Reserved
0000b...1111b
35.106 DOL starter event
type
No action
Warning
Fault
36

36 Load analyzer

36.01
PVL signal source
Zero
Motor speed used
Description
Defines a feedback delay for the motor fan.
The delay timer starts when bit 1 of
feedback is received from the fan until the delay elapses, the
action selected by
35.106
Note: This delay is only applied at start. If the feedback signal
is lost during run, the action selected by
immediately.
Motor fan start delay.
Status of the motor fan control logic.
Bit 1 is the control output for the fan, to be selected as the
source of, for example, a digital or relay output.
The other bits indicate the statuses of the selected control
and feedback sources, and the fault status.
This parameter is read-only.
Description
Status of fan control source selected by 35.100.
0 = Stop requested
1 = Start requested
Fan control bit (delays observed). Select this bit as the source of the
output controlling the fan.
0 = Stopped
1 = Started
Status of fan feedback (source selected by 35.103).
0 = Stopped
1 = Running
Fault status.
0 = Fault (fan feedback missing). The action taken is selected by
35.106.
1 = No fault
Status of motor fan control logic.
Selects the action taken when missing fan feedback is
detected by the motor fan control logic.
No action taken.
The drive generates a warning
Drive trips on
71B1 Motor
Peak value and amplitude logger settings.
See also section
Load analyzer
Selects the signal to be monitored by the peak value logger.
The signal is filtered using the filtering time specified by
parameter
36.02 PVL filter
The peak value is stored, along with other pre-selected
signals at the time, into parameters 36.10...36.15.
The peak value logger can be reset using parameter
Reset
loggers. The logger is also reset whenever the signal
source is changed. The date and time of the last reset are
stored into parameters
36.16
None (peak value logger disabled).
01.01 Motor speed used
35.105
switches on. If no
is taken.
35.106
is taken
(A781 Motor
fan).
fan.
(page 124).
time.
and
36.17
respectively.
(page 152).
Def/FbEq16
0 s; 5 s
(95.20
b6)
1 = 1 s
-
1 = 1
Fault
0
1
2
Power inu
out
36.09
0
1