ABB +N5600 Firmware Instructions page 166

Single drive
Table of Contents

Advertisement

166 Parameters
No.
Name/Value
06.04
FBA B transparent
control word
00000000h ...
FFFFFFFFh
06.05
EFB transparent
control word
00000000h ...
FFFFFFFFh
06.11
Main status word
0000h...FFFFh
Description
Displays the unaltered control word received from the PLC
through fieldbus adapter B when a transparent
communication profile is selected eg. by parameter group
FBA B
settings. See section
(page 634).
This parameter is read-only.
Control word received through fieldbus adapter B.
Displays the unaltered control word received from the PLC
through the embedded fieldbus interface when a transparent
communication profile is selected in parameter
profile. See section
The Transparent profile
This parameter is read-only.
Control word received through the embedded fieldbus
interface.
Main status word of the drive.
The bit assignments are described on page 638. The related
control word and state diagram are presented on pages
and
639
respectively.
This parameter is read-only.
Main status word.
Control word and Status word
58.25 Control
(page 624).
Def/FbEq16
-
54
1 = 1
-
1 = 1
-
637
1 = 1