Code
Warning
(hex)
A497
Motor temperature 1
(Editable message text)
A498
Motor temperature 2
(Editable message text)
A499
Motor temperature 3
(Editable message text)
A4A0
Control board
temperature
A4A1
IGBT overtemperature Estimated drive IGBT
A4A9
Cooling
A4B0
Excess temperature
Cause
The thermistor protection
module installed in slot 1
indicates overtemperature.
The thermistor protection
module installed in slot 2
indicates overtemperature.
The thermistor protection
module installed in slot 3
indicates overtemperature.
Control unit temperature is
excessive.
(none) Temperature above warning
limit
1 Thermistor broken
temperature is excessive.
Drive module temperature is
excessive.
Power unit temperature is
excessive.
Fault tracing 571
What to do
Check the cooling of the motor.
Check the motor load and drive ratings.
Check the wiring of the temperature
sensor. Repair wiring if faulty.
Measure the resistance of the sensor.
Replace sensor if faulty.
Check the auxiliary code. See actions for
each code below.
Check ambient conditions.
Check air flow and fan operation.
Check heatsink fins for dust pick-up.
Contact an ABB service representative
for control unit replacement.
Check ambient conditions.
Check air flow and fan operation.
Check heatsink fins for dust pick-up.
Check motor power against drive power.
Check ambient temperature. If it exceeds
40 °C (104 °F), ensure that load current
does not exceed derated load capacity of
drive. See appropriate Hardware manual.
Check drive module cooling air flow and
fan operation.
Check inside of cabinet and heatsink of
drive module for dust pick-up. Clean
whenever necessary.
Check ambient conditions.
Check air flow and fan operation.
Check heatsink fins for dust pick-up.
Check motor power against drive power.
Check the auxiliary code (format XXXY
YYZZ). "Y YY" specifies through which
BCU control unit channel the fault was
received. "ZZ" specifies the location (1:
U-phase, 2: V-phase, 3: W-phase, 4: INT
board, 5: Brake chopper, 6: Air inlet
(sensor connected to INT board X10), 7:
PCB compartment fan or power supply
board, 8: du/dt filter or temperature
switch (XT) (sensor connected to INT
board X7), 9: Sensor connected to INT
board X6, 0FA: Ambient temperature).