404 Parameters
No.
Name/Value
60.60
DDCS controller
ref1 type
Auto
Transparent
General
Torque
Speed
Frequency
60.61
DDCS controller
ref2 type
60.62
DDCS controller
act1 type
Auto
Transparent
General
Torque
Speed
Frequency
60.63
DDCS controller
act2 type
Auto
Transparent
General
Torque
Speed
Frequency
60.64
Mailbox dataset
selection
Dataset 32/33
Description
Selects the type and scaling of reference 1 received from the
external controller. The resulting value is shown by
DDCS controller ref
1.
Type and scaling are chosen automatically according to
which reference chain (see settings Torque, Speed,
Frequency) the incoming reference is connected to. If the
reference is not connected to any chain, no scaling is applied
(as with setting Transparent).
No scaling is applied.
Generic reference with a scaling of 100 = 1 (ie. integer and
two decimals).
The scaling is defined by parameter
The scaling is defined by parameter
The scaling is defined by parameter
Selects the type and scaling of reference 2 received from the
external controller. The resulting value is shown by
DDCS controller ref
2.
For the selections, see parameter
type.
Selects the type/source and scaling of actual value ACT1
transmitted to the external controller.
Type/source and scaling follow the type of reference 1
selected by parameter
60.60 DDCS controller ref1
the individual settings below for the sources and scalings.
Reserved.
Reserved.
01.10 Motor torque
is sent as actual value 1. The scaling is
defined by parameter
46.03 Torque
01.01 Motor speed used
is defined by parameter
01.06 Output frequency
is defined by parameter
Selects the type/source and scaling of actual value ACT2
transmitted to the external controller.
Type/source and scaling follow the type of reference 2
selected by parameter
60.61 DDCS controller ref2
the individual settings below for the sources and scalings.
Reserved.
Reserved.
01.10 Motor torque
is sent as actual value 2. The scaling is
defined by parameter
46.03 Torque
01.01 Motor speed used
is defined by parameter
01.06 Output frequency
is defined by parameter
Selects the pair of data sets used by the mailbox service in
the drive/controller communication.
See section
External controller interface
Data sets 32 and 33.
46.03 Torque
46.01 Speed
46.02 Frequency
60.60 DDCS controller ref1
scaling.
is sent as actual value 1. The scaling
46.01 Speed
scaling.
is sent as actual value 1. The scaling
46.02 Frequency
scaling.
scaling.
is sent as actual value 2. The scaling
46.01 Speed
scaling.
is sent as actual value 2. The scaling
46.02 Frequency
scaling.
(page 75).
Def/FbEq16
Auto
03.11
0
1
2
scaling.
3
scaling.
4
scaling. 5
Auto
03.12
Auto
0
type. See
1
2
3
4
5
Auto
0
type. See
1
2
3
4
5
Dataset
32/33
0

Hide quick links: