446 Parameters
No.
Name/Value
81.82
Until next cleaning
00 00:00...99 00:00
81.99
Cleaning status
word
Bit
Name
0
Cleaning started
1
Cleaning requested
2
First step
3
Off step
4
Second step
5
Cleaning done
6
Aborted by supervision
7
Acceleration boost act
8...10
Reserved
11
Requested by manual
trigger
12
Requested by timer
13...14 Reserved
15
Max cleanings detected
77
85 Q-H pump curves
85.01
Pump curve input
function
NULL
Input 1 Direct
Input 2 Direct
Input 1 + Input 2
Input 1 - Input 2
Input 1 * Input 2
Input 1 / Input 2
Other
85.02
Input 1 source
Description
Displays the time remaining before next cleaning request is
initiated by the Time trigger function.
Until next cleaning.
Displays status word for the pump cleaning function.
Description
Cleaning operation is active.
Cleaning request is issued. Cleaning will
be performed on the next drive start.
First step is active.
Off step is active.
Second step is active.
Cleaning procedure has been completed
on last start.
Cleaning aborted by the low/high
supervision.
Cleaning acceleration boost active.
Cleaning requested from the manual
trigger source.
Cleaning requested by the time trigger.
Maximum allowed number of cleanings
has been reached.
Estimates flowrate of pump curves in ESP application.
See section
Pump curves
Selects the method for the pump curve input processing.
The user has two source parameters for the pump curve input
(85.02 Input 1 source
and
input for the pump curve function could be either of source
parameters or result of math operation between the two.
Zero
Parameter
85.02 Input 1 source
function.
Parameter
85.03 Input 2 source
function.
Sum of
85.02 Input 1 source
input of pump curves function.
Difference of
85.02 Input 1 source
the input of pump.
Multiply of
85.02 Input 1 source
the input of pump curves function.
Division of
85.02 Input 1 source
the input of pump curves function.
Source selection (see
Terms and abbreviations
Defines source 1 for signal that can be used as an input for
the pump curve function.
(page 60).
85.03 Input 2
source). The used
is input for pump curves
is input for pump curves
and
85.03 Input 2 source
and
85.03 Input 2 source
and
85.03 Input 2 source
and
85.03 Input 2 source
on page 148).
Def/FbEq16
00 00:00
-
0b0000
Input 1 -
Input 2
is the
is
is
is
Aux input
data 1