154 Parameters
No.
Name/Value
01.30
Nominal torque
scale
0.000... N·m or lb·ft Nominal torque.
01.31
Ambient
temperature
-40 ... 120 °C or °F
01.32
Inverter GWh
regenerating
0...32767 GWh
01.33
Inverter MWh
regenerating
0...999 MWh
01.34
Inverter kWh
regenerating
0...999 kWh
01.35
Mot - regen energy
GWh
-32768...32767
GWh
01.36
Mot - regen energy
MWh
-999...999 MWh
01.37
Mot - regen energy
kWh
-999...999 kWh
01.61
Abs motor speed
used
0.00 ... 30000.00
rpm
01.62
Abs motor speed%
0.00 ... 1000.00%
01.63
Abs output
frequency
0.00 ... 500.00 Hz
01.64
Abs motor torque
0.0 ... 1600.0%
Description
Torque that corresponds to 100% of nominal motor torque.
The unit is selected by parameter
Note: This value is copied from parameter
nominal torque
if entered. Otherwise the value is calculated
from other motor data.
Measured temperature of incoming cooling air. The unit is
selected by parameter
96.16 Unit
Cooling air temperature.
Amount of energy that has passed through the drive (towards
the supply) in full gigawatt-hours. The minimum value is zero.
Regenerative energy in GWh.
Amount of energy that has passed through the drive (towards
the supply) in full megawatt-hours. Whenever the counter
rolls over,
01.32 Inverter GWh regenerating
incremented.The minimum value is zero.
Regenerative energy in MWh.
Amount of energy that has passed through the drive (towards
the supply) in full kilowatt-hours. Whenever the counter rolls
over,
01.33 Inverter MWh regenerating
minimum value is zero.
Regenerative energy in kWh.
Amount of net energy (motoring energy - regenerating
energy) that has passed through the drive in full gigawatt-
hours.
Energy balance in GWh.
Amount of net energy (motoring energy - regenerating
energy) that has passed through the drive in full megawatt-
hours. Whenever the counter rolls over,
energy GWh
is incremented or decremented.
Energy balance in MWh.
Amount of energy (motoring energy - regenerating energy)
that has passed through the drive in full kilowatt-hours.
Whenever the counter rolls over,
MWh
is incremented or decremented.
Energy balance in kWh.
Absolute value of
01.01 Motor speed
Measured or estimated motor speed.
Absolute value of
01.03 Motor speed
Measured or estimated motor speed.
Absolute value of
01.06 Output
Estimated output frequency.
Absolute value of
01.10 Motor
Motor torque.
96.16 Unit selection
99.12 Motor
selection.
is
is incremented.The
01.35 Mot - regen
01.36 Mot - regen energy
used.
%.
frequency.
torque.
Def/FbEq16
-
1 = 1 unit
-
1 = 1°
-
1 = 1 GWh
-
1 = 1 MWh
-
10 = 1 kWh
-
1 = 1 GWh
-
1 = 1 MWh
-
10 = 1 kWh
-
See par.
46.01
-
10 = 1%
-
See par.
46.02
-
See par.
46.03

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents