ABB +N5600 Firmware Instructions page 179

Single drive
Table of Contents

Advertisement

No.
Name/Value
06.101 User control word 2
Bit
Name
0
User control word 2 bit 0
1
User control word 2 bit 1
...
...
15
User control word 2 bit 15 User-defined bit.
0000h...FFFFh
06.116
LSU drive status
word 1
Bit
Name
0
Enabled
1
Inhibited
2
Operation
allowed
3
Ready to start 1 = Drive is ready to receive a start command
4
Running
5
Started
6
Modulating
7
Limiting
8
Local control
9
Network
control
10
Ext1 active
11
Ext2 active
12
Charging relay 1 = Charging relay is closed
13
MCB relay
14...15 Reserved
0000h...FFFFh
Description
User-defined control word 2.
Description
User-defined bit.
User-defined bit.
...
User-defined control word 2.
(Only visible when IGBT supply unit control activated by
95.20)
Drive status word 1 received from the supply unit.
See also section
Control of a supply unit (LSU)
and parameter group
60 DDCS
This parameter is read-only.
Description
1 = Run enable and start enable signals are present
1 = Start inhibited
1 = Drive is ready to operate
1 = Drive is ready to follow given reference
1 = Drive has been started
1 = Drive is modulating (output stage is being controlled)
1 = Any operating limit is active
1 = Drive is in local control
1 = Drive is in network control
1 = Control location Ext1 active
1 = Control location Ext2 active
1 = MCB relay is closed
Drive status word 1.
Parameters 179
(page 77),
communication.
Def/FbEq16
-
1 = 1
-
1 = 1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents