ABB +N5600 Firmware Instructions page 462

Single drive
Table of Contents

Advertisement

462 Parameters
No.
Name/Value
FSE-31
91.12
Module 1 location
Slot 1
Slot 2
Slot 3
4...254
91.13
Module 2 type
None
FEN-01
FEN-11
FEN-21
FEN-31
FSE-31
91.14
Module 2 location
Slot 1
Slot 2
Slot 3
4...254
91.21
Module 1 temp
sensor type
None
PTC
KTY-84
91.22
Module 1 temp filter
time
0...10000 ms
91.24
Module 2 temp
sensor type
None
PTC
KTY-84
91.25
Module 2 temp filter
time
0...10000 ms
91.31
Module 1 TTL
output source
Not selected
Description
FSE-31.
Specifies the slot (1...3) on the control unit of the drive into
which the interface module is installed. Alternatively, specifies
the node ID of the slot on an FEA-03 extension adapter.
Slot 1.
Slot 2.
Slot 3.
Node ID of the slot on the FEA-03 extension adapter.
Defines the type of the module used as interface module 2.
None (communication disabled).
FEN-01.
FEN-11.
FEN-21.
FEN-31.
FSE-31.
Specifies the slot (1...3) on the control unit of the drive into
which the interface module is installed. Alternatively, specifies
the node ID of the slot on an FEA-03 extension adapter.
Slot 1.
Slot 2.
Slot 3.
Node ID of the slot on the FEA-03 extension adapter.
Specifies the type of temperature sensor connected to
interface module 1. Note that the module must also be
activated by parameters 91.11...91.12.
None.
PTC. (The unit is ohms.)
KTY84. (The unit is selected by parameter
selection.)
Defines a filtering time for the temperature measurement
through interface module 1.
Filtering time for temperature measurement.
Specifies the type of temperature sensor connected to
interface module 2. Note that the module must also be
activated by parameters 91.13...91.14.
None.
PTC. (The unit is ohms.)
KTY84. (The unit is selected by parameter
selection.)
Defines a filtering time for the temperature measurement
through interface 2.
Filtering time for temperature measurement.
Selects the encoder input on interface module 1 whose signal
is echoed by or emulated to the TTL output.
See also section
Encoder support
TTL output not in use.
96.16 Unit
96.16 Unit
(page 86).
Def/FbEq16
5
Slot 2
1
2
3
1 = 1
None
0
1
2
3
4
5
Slot 3
1
2
3
1 = 1
None
0
1
2
1500 ms
-
None
0
1
2
1500 ms
-
Not selected
0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents