5-20

Replacing the Upper Scoring Rollers

Press the Emergency Stop button.
Open the cover feed section cover.
Remove the shaft for the upper scoring
rollers.
(1) Loosen the hex bolt at each end.
(2) Turn the clamp block at each end, and remove
the shaft.
Shaft For The Upper
Scoring Rollers
Hex Bolts
Clamp Block
Cover Feed
Section Cover
22064
50401A1
5
22064
51901A1
177