The Tank Temperature Does Not Rise; The Books Do Not Drop Easily - Horizon Fitness BOOK BINDER BQ-470 Important Information Manual

Table of Contents

Advertisement

4-7
Problems with the Main Part of the Machine

4-7-7 The tank temperature does not rise

Where to check
The display
Circuit Breaker For
on the
The Tank Heater
temperature
controller is
blank.
The thermal
fuse has
blown.

4-7-8 The books do not drop easily

Where to check
The level
plate return
operation
setting has
been
changed.
The book
blocks are
leaning on the
book block
support guide
of the carriage
clamp.
Glue, etc. is
Check
stuck inside
the carriage
clamp.
The clamp
opening is too
narrow so that
when the
books are
delivered,
they are
caught.
Cause and solution
• Check whether the circuit breaker for the tank heater has
tripped.
22064
40706A1
• Replace the thermal fuse.
22064
40706B1
Cause and solution
• Set the level plate return operation on the Bookbinding –
Operation screen to
Start buttons to return the level plate.
22064
40707A1
• Replace the book block support guide with one which is
designed for a higher spine.
High
22064
40707B1
• Remove any stuck glue which is interfering with the
books.
22064
40707C1
• Increase the clamp width using the Bookbinding - Fine-
Tune Adjustment - Clamp/Milling/Nipper/Delivery screen.
22064
40302A1
, and press the Bookbinding
Related
item
5-17
5-19
4
Related
item
1-3-2
3-5
1-3-2
123