4-3
Spine-Related Problems
4-3-1 The spines on the covers are dented
Where to check
There are some
lumps of glue in the
nipping section.
There are some
lumps of glue in the
delivery section.
4-3-2 One side of the spine is dented
Where to check
The clamp opening is
too narrow so that
when the books are
delivered, they are
caught and fall on
one edge.
4-3-3 Thick books - spines are creased
Where to check
Nipping is set to
"nipping for book with
milling."
The nipping delay
time is too short.
Cause and solution
• Clean the nipping section.
22064
40301A1
• Clean the delivery section.
22064
40301B1
Cause and solution
• Increase the clamp width using the
Bookbinding - Fine-Tune Adjustment -
Clamp/Milling/Nipper/Delivery screen.
22064
40302A1
Cause and solution
• Select the
operation setting using the Bookbinding –
Settings screen.
22064
40207A1
• Increase the nipping delay time using the
Bookbinding - Fine-Tune Adjustment -
Clamp/Milling/Nipper/Delivery screen.
22064
40303A1