4.2.2
Setting the frequency by switches (multi-speed setting)
• Use the operation panel (
• Turn ON the RH, RM, or RL signal to give a frequency command. (multi-speed setting)
• Set Pr.79 Operation mode selection="4" (External/PU combination operation mode 2).
[Connection diagram]
High speed
Middle speed
Low speed
Switch
The following shows the procedure to operate at a low speed (10 Hz).
Operating procedure
1.
Screen at power-ON
The monitor display appears.
2.
Changing the operation mode
Set "4" in Pr.79. [PU+E] indicator is on.
3.
Setting the frequency
Turn ON the low-speed switch (RL).
4.
Start → acceleration → constant speed
Press
or
and "10.00 Hz" appears.
5.
Deceleration → stop
Press
to stop. The frequency value on the indication decreases in Pr.8 Deceleration time, and the motor
stops rotating with "0.00 Hz" displayed. Turn OFF the low-speed switch (RL).
NOTE
• The terminal RH is initially set to 60 Hz. The terminal RM is set to 30 Hz, and the RL is set to 10 Hz. (To change, set Pr.4,
Pr.5, and Pr.6.)
• In the initial setting, when two or more of multi-speed settings are simultaneously selected, priority is given to the set
frequency of the lower signal. For example, when RH and RM signals turn ON, RM signal (Pr.5) has a higher priority.
• Maximum of 15-speed operation can be performed.
Parameters referred to
Pr.4 to Pr.6 (multi-speed setting)
Pr.7 Acceleration time, Pr.8 Deceleration time
Pr.79 Operation mode selection
or
) to give a start command.
Inverter
RH
Operation panel
RM
RL
SD
to start running. The frequency value on the indication increases in Pr.7 Acceleration time,
page 226
page 190
page 204
Speed 1
(High speed)
Speed 2
(Middle speed)
Speed 3
(Low speed)
Time
ON
RH
ON
RM
ON
RL
4. BASIC OPERATION
4.2 Basic operation procedure (PU operation)
3
4
5
4
5
6
7
8
9
10
91

Advertisement

Table of Contents
loading

Table of Contents