 Adjusting the response of terminal AM (Pr.867)
• Using Pr.867, the output voltage response of the terminal AM can be adjusted in the range of 0 to 5 s.
• Increasing the setting stabilizes the terminal AM output more but reduces the response level. (Setting "0" sets the response
level to 7 ms.)
Parameters referred to
Pr.54 CA terminal function selection
Pr.55 Frequency monitoring reference
Pr.56 Current monitoring reference
Pr.158 AM terminal function selection
Pr.290 Monitor negative output selection
Pr.291 Pulse train I/O selection
290
5. PARAMETERS
5.8 (M) Monitor display and monitor output signal
page 284
page 284
page 284
page 284
page 284
page 222