Mitsubishi Electric 800 Series Instruction Manual page 300

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Setting
Signal
name
Positive
Negative
logic
logic
45
145
RUN3
46
146
Y46
47
147
PID
48
148
Y48
49
149
Y49
50
150
Y50
51
151
Y51
52
152
Y52
53
153
Y53
54
154
Y54
57
157
IPM
64
164
Y64
65
165
Y65
66
166
ALM3
67
167
Y67
68
168
EV
70
170
SLEEP PID output interruption
71
171
RO1
72
172
RO2
73
173
RO3
74
174
RO4
75
175
RIO1
76
176
RIO2
77
177
RIO3
78
178
RIO4
79
179
Y79
80
180
82
182
Y82
85
185
Y85
Function
Inverter running and start
Output while the inverter is running and the start
command is ON
command is ON.
During deceleration at
Output after the power-failure deceleration
occurrence of power failure
function operates. (Retained until canceled.)
During PID control activated Output during PID control.
PID deviation limit
Output when the absolute deviation value
exceeds the limit value.
During pre-charge operation Output during pre-charge operation.
During second pre-charge
operation
Pre-charge time over
Output when the pre-charge operation reaches
the time limit set in Pr.764 or Pr.769.
Second pre-charge time
over
Pre-charge level over
Output when the measured value before
reaching the ending time during pre-charge
Second pre-charge level
operation is higher than the detection level set in
over
Pr.763 or Pr.768.
During PM motor control
Output while the control method is PM motor
control.
During retry
Output during retry processing.
Output during emergency drive operation.
Emergency drive in
*2
operation
Fault output during
Output when a fault occurs during emergency
drive operation.
*2
emergency drive
*3
Output when the power failure time
Power failure
deceleration-to-stop function is activated during
output shutoff due to power failure or
undervoltage.
24 V external power supply
Output while operating with a 24 V power supply
operation
input from an external source.
Output during PID output suspension function
operation.
Commercial power supply
Output depending on the motor drive conditions
side motor 1 connection
when the multi-pump function is used.
RO1
Commercial power supply
side motor 2 connection
RO2
Commercial power supply
side motor 3 connection
RO3
Commercial power supply
side motor 4 connection
RO4
Inverter side motor 1
connection RIO1
Inverter side motor 2
connection RIO2
Inverter side motor 3
connection RIO3
Inverter side motor 4
connection RIO4
Pulse train output of output
Output in pulses every time the accumulated
power
output power of the inverter reaches the Pr.799
setting.
For manufacturer setting. Do not set.
BACnet binary output
Enables output from the Binary Output object for
BACnet communication.
Output when there is a power failure or
*2
DC current feeding
undervoltage for the AC current.
Operation
Pr.261 to Pr.266
Pr.127 to Pr.134,
Pr.575 to Pr.577
Pr.127 to Pr.134,
Pr.553, Pr.554
Pr.127 to Pr.134,
Pr.241, Pr.553,
Pr.554, Pr.575 to
Pr.577, Pr.753 to
Pr.769, C42 to
C45
Pr.71, Pr.80,
Pr.998
Pr.65 to Pr.69
Pr.514, Pr.515,
Pr.523, Pr.524,
Pr.1013
Pr.261 to Pr.266
Pr.127 to Pr.134,
Pr.575 to Pr.577
Pr.575 to Pr.591
Pr.799
Pr.549
Pr.30
5.8 (M) Monitor display and monitor output signal
Related
Refer
parameter
to
3
page
303
4
458
396
5
396
424
5
5
6
151
242
245
7
8
458
9
63
396
10
429
315
516
553
299
5. PARAMETERS