 Operation at fault
Fault type
(Pr.551 setting)
Inverter fault
PU connector
2 (PU connector)
disconnection
9999 (automatic
recognition)
Other than 2
Communication
2 (PU connector)
error at PU
connector
Other than 2
Communication
1 (RS-485
error at RS-485
terminals)
terminals
Other than 1
Communication
3 (USB connector)
error at USB
9999 (automatic
connector
recognition)
Other than 3
Communication
error at
communication
option
*1
Selectable with Pr.75 Reset selection/disconnected PU detection/PU stop selection
*2
Selectable with Pr.122 PU communication check time interval, Pr.336 RS-485 communication check time interval, and Pr.548 USB
communication check time interval
*3
Follows the communication option
*4
In the PU JOG operation mode, operation always stops when the PU is disconnected. The operation of PU disconnection (E.PUE) follows the
Pr.75 Reset selection/disconnected PU detection/PU stop selection setting.
*5
When Pr.550 NET mode operation command source selection= "1" (RS-485 terminals enabled), or Pr.550 NET mode operation command
source selection="9999" with no communication option connected.
*6
When Pr.550 NET mode operation command source selection="0" (communication option enabled), or Pr.550 NET mode operation
command source selection="9999" with communication option connected.
218
5. PARAMETERS
5.6 (D) Operation command and frequency command
Conditions
PU operation
Stop
Stop/continued
Stop/continued
Stop/
*2
continued
Continued
Stop/
*2
continued
Continued
Stop/
*2
continued
Continued
Continued
Operation in each operation mode at error occurrences
External
Combined
operation
operation
mode 1
(Pr.79 =3)
*1*4
*1
Continued
Stop/
continued
Continued
Stop/
continued
Continued
Combined
NET operation
operation
(via RS-485
*5
mode 2
terminals)
(Pr.79 =4)
Continued
*2
Continued
*2
Stop/continued
*2
NET operation
*6
(via option)
Continued
Stop/continued
*3