Mitsubishi Electric 800 Series Instruction Manual page 284

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

• Select items to be displayed with minus signs using Pr.1018 Monitor with sign selection.
Monitor item
Output frequency
Motor speed
Motor torque
PID deviation
BACnet Terminal AM output level
Remote output 1
Remote output 2
Remote output 3
Remote output 4
PID manipulated amount
Second PID deviation
Second PID manipulated amount
Control circuit temperature
○: Displayed with minus signs, —: Displayed without minus signs (unsigned numbers only)
*1
Displayed without minus signs on the operation panel. Confirm the rotation direction with the [FWD] or [REV] indicator.
NOTE
• When indication with negative numbers is enabled for the output via terminal AM (analog voltage output), the output is
within the range of -10 to +10 VDC. Connect a meter suitable for the output.
• Parameter unit (FR-PU07) displays only unsigned numbers.
 Monitor filter (Pr.1106 to Pr.1108)
• The response level (filter time constant) of the following monitor indicators can be adjusted.
Pr.
Monitor number
1106
7
17
1107
6
1108
18
Parameters referred to
Pr.30 Regenerative function selection
Pr.37 motor speed display, Pr.144 Speed setting switchover
Pr.55 Frequency monitoring reference, Pr.56 Current monitoring reference, Pr.866 Torque monitoring reference
page 284
Pr.1018 setting
9999
Monitor indicator name
Motor torque
Load meter
Running speed
Motor excitation current
page 553
page 272
0, 1
*1
*1
5.8 (M) Monitor display and monitor output signal
3
4
5
5
5
6
7
8
9
10
283
5. PARAMETERS